Inspection number: 303411 Client: John Smith Date: March 9, 2003 Inspector: Jeff Ermis Time: 1:00 PM Address: 150 Main Street, San Diego, CA
This home is a two level, detached single family dwelling. Weather at time of inspection was warm and sunny. The information contained in this report is subject to the terms and conditions stated in the "Inspection Agreement". The report is based on a non-invasive physical examination to identify material defects in the systems, structures, and components of the accessible areas of the property as they exist at time of inspection. The inspection was performed in compliance with the Standards of Practice established by the California Real Estate Inspection Association. 100 EXTERIOR Our inspection is visual and based on our experience and knowledge of building materials and techniques. Normal wear is not taken into consideration in our review. 101 Lot/Grade: Home is built on a steeply sloped hillside lot. Surface grading and drainage observations are limited to areas within six feet of inspected structures. Adjacent surface drainage appears to be adequate. Geologic and engineering evaluations are beyond the scope of this report, client is advised to consult a specialist if concerned by conditions noted in this report, or that you have observed. 102 Driveway: Concrete, S. 103 Walks: Wood. Recommend evaluation by pest control specialist. Distance between railing balusters greater than four inches, potential hazard to toddlers. 104 Siding/trim: Wood. Overall siding and trim appears to be serviceable. Evidence of previous water intrusion indicated by water stains on interior walls and ceilings, stains appear to be older. Recommend evaluation by pest control specialist. 105 Window types: Dual glazed metal framed horizontal sliders and wood framed fixed. 106 Electrical fixtures: S. 107 Door chime: S. 108 Chimney type: Pre-fabricated. Equipped with flue cap. 109 Foundation: Raised with concrete stem walls and pier and post construction. Access located at rear. Observed foundation appears to be serviceable. Framing is bolted to foundation. Ventilation appears to be adequate. Additional cable reinforcements noted. 110 Comments: N. 200 BALCONY 201 Decks: Wood. Recommend evaluation by pest control specialist. 202 Stairs/railing: S. Distance between balusters greater than four inches, potential hazard to toddlers. 203 Electrical: Reversed polarity outlet at upper balcony, recommend repairs. 204 Comments: N.
300 ROOF Our evaluation of the roof is to determine if portions are missing and/or deteriorating and, therefore, subject to possible leaking. Some portions of roof underlayment and sub-structures are hidden from view and cannot be inspected by our inspectors, our evaluation is not a guarantee against leaks or failure. 301 Observation points: Ladder. Roof not mounted by inspector. 302 Type: Sloped. 303 Construction: Open beam. 304 Roof material: Composition shingles. 305 Condition: Overall observed roof appears to be serviceable. 306 Flashing: Observed flashing appears to be serviceable. 307 Gutters: N. 308 Comments: N. 500 LAUNDRY CLOSET 501 Floor: Resilient. 502 Doors: S. 503 Walls: S. 504 Ceiling: S. 505 Windows/screens: N. 506 Electrical: S. 507 Exhaust fan: N. 508 Washer hook-up: Present, valves are not tested or hoses disconnected. 509 Dryer hook-up: Gas. 510 Comments: N. 550 FIREPLACE 551 Location: Living room. Equipped with gas service. Damper, S.
600 UTILITIES/MAJOR SYSTEMS Our major systems evaluation is both visual and functional provided electrical, gas, and plumbing supplies are activated. Water flow sufficiency in plumbing or cooling efficiency in air conditioning systems is a subjective evaluation, therefore, we only note a poor condition if the inspector's observations and experience suggest inadequate operation. We advise you to operate these systems prior to close of escrow.
610 Gas service: Located at front of house.
620 Electrical: 120/240 volt above ground service. Main panel with 100 amp main shut-off located at right front of house. Equipped with circuit breakers, grounding system and copper low amperage branch wiring. Right front exterior outlet not equipped with GFCI protection, recommend upgrade to enhance safety.
630 Plumbing: Public supply. Shut-off located at front. Copper supply lines. Public waste system. ABS plastic drain lines.
640 Water heater: Gas-fired located in crawl space. Unable to determine size, obscured by insulation blanket. Equipped with gas and water shut-offs. Operated. Venting, TPR valve and discharge pipe appear to be functional. No evidence of leaks at time of inspection. Existing strapping does not comply with current retrofit standards, advise corrective action.
650 Heating: Gas, forced air heater located in crawl space. Equipped with gas and electrical disconnects. Operated. Thermostat, venting, blower and ducting were functional at time of inspection. Combustion air supply appears to be adequate. Dirty filter.
660 Smoke detector: Located in lower hall, tested and functional at time of inspection.
The interior inspection is visual and functional in nature. In some homes various areas are obscured from view by personal property. As mentioned in the Inspection Agreement, we do not inspect for hazardous materials or their usage in construction materials. Pests, wood destroying organisms, mold and mildew investigations are not within the scope of this inspection. If client is concerned about items not within the scope of the inspection we recommend consulting the appropriate specialist. 700 ENTRY/LIVING ROOM 701 Floor: Carpet and resilient. 702 Doors: S. 703 Walls: S. 704 Ceiling: S. Water stains noted at left of upper left front window, unable to determine if active leak. 705 Windows/screens: S. 706 Electrical: S. 707 Comments: N.
760 HALL/STAIRS 761 Floors: Carpet. 762 Doors: S. 763 Walls: S. 764 Ceiling: S. 765 Windows/screens: N. 766 Electrical: S. 767 Stairs/railing: S. Distance between balusters greater than four inches, potential hazard to toddlers. 768 Comments: N.
800 BEDROOM-Master 801 Floor: Carpet. 802 Doors: S. 803 Walls: S. 804 Ceiling: S. 805 Windows/screens: S. 806 Electrical: S. 807 Closets: S. 808 Comments: N.
810 BEDROOM-Guest 811 Floor: Carpet. 812 Doors: S. 813 Walls: S. 814 Ceiling: S. Water stains noted at upper left of side window, unable to determine if active leaks. 815 Windows/screens: S. 816 Electrical: S. 817 Closets: S. 818 Comments: N.
900 KITCHEN The kitchen inspection is visual and functional. Energized appliances are operated. Calibrations of cooking equipment is not considered, nor are life expectancies given to appliances. Due to their complexity, dishwashers can fail at any time, our review is to evaluate leakage and corrosion. Self-cleaning cycles on ovens are not operated. 901 Floor: Resilient. 902 Doors: N. 903 Walls: S. 904 Ceiling: S. Water stains noted above side window, unable to determine if active leaks. 905 Windows/screens: S. 906 Electrical: S. Outlets not equipped with GFCI protection, recommend upgrade to enhance safety. 907 Counter tops: S. 908 Cabinets: S. 909 Sinks: S. 910 Faucets: S. 911 Plumbing: S. 912 Disposal: Operated, S. 913 Dishwasher: Operated, S. 914 Oven: Gas. Operated, S. 915 Stove/cook top: Gas. Operated, S. 916 Hood/fan: S. 917 Comments: N.
1000 BATHROOM-Upper Our bathroom evaluation is directed towards visible water damage or plumbing problems. Common problems are stuck or missing stoppers or dripping faucets. 1001 Floors: Resilient. 1002 Doors: S. 1003 Walls: S. 1004 Ceiling: S. 1005 Windows/screens: S. 1006 Electrical: S. 1007 Exhaust fan: N. 1008 Heating: Ceiling mounted electric heater, S. 1009 Tub & surrounding: N. 1010 Tub enclosure: N. 1011 Tub faucet: N. 1012 Shower head: Disrepair to mount. 1013 Shower faucet: S. 1014 Shower/surrounding: Tile. Negative sloping of threshold not to industry standards, extensive use of caulking observed at door frame. Loose outer tiles, cracked grout at lower left of door. 1015 Shower door: S. 1016 Sinks: S. 1017 Sink faucets: S. 1018 Plumbing: S. 1019 Toilet: S. 1020 Counter/cabinets: S. Medicine cabinet door strikes light fixture when fully opened. 1021 Comments: N.
1100 BATHROOM-Lower 1101 Floors: Resilient. 1102 Doors: S. 1103 Walls: S. 1104 Ceiling: S. 1105 Windows/screens: S. 1106 Electrical: Inoperable test button at GFCI outlet, recommend repair. 1107 Exhaust fan: N. 1108 Heating: Ceiling mounted electric heater, S. 1109 Tub & surrounding: Tile, S. Loose tiles, missing grout at lower right outer side of tub. 1110 Tub enclosure: N. 1111 Tub faucet: S. 1112 Shower head: S. 1113 Shower faucet: S. 1114 Shower/surrounding: N. 1115 Shower door: N. 1116 Sinks: S. 1117 Sink faucets: S. 1118 Plumbing: S. 1119 Toilet: S. 1120 Counter/cabinets: S. See #1020. 1121 Comments: N. |
|